loading
Automatic Irrigation Doser Pump 0.4-4% Fertilizer for Poultry 1
Automatic Irrigation Doser Pump 0.4-4% Fertilizer for Poultry 2
Automatic Irrigation Doser Pump 0.4-4% Fertilizer for Poultry 3
Automatic Irrigation Doser Pump 0.4-4% Fertilizer for Poultry 4
Automatic Irrigation Doser Pump 0.4-4% Fertilizer for Poultry 5
Automatic Irrigation Doser Pump 0.4-4% Fertilizer for Poultry 6
Automatic Irrigation Doser Pump 0.4-4% Fertilizer for Poultry 7
Automatic Irrigation Doser Pump 0.4-4% Fertilizer for Poultry 1
Automatic Irrigation Doser Pump 0.4-4% Fertilizer for Poultry 2
Automatic Irrigation Doser Pump 0.4-4% Fertilizer for Poultry 3
Automatic Irrigation Doser Pump 0.4-4% Fertilizer for Poultry 4
Automatic Irrigation Doser Pump 0.4-4% Fertilizer for Poultry 5
Automatic Irrigation Doser Pump 0.4-4% Fertilizer for Poultry 6
Automatic Irrigation Doser Pump 0.4-4% Fertilizer for Poultry 7

Automatic Irrigation Doser Pump 0.4-4% Fertilizer for Poultry

5.0
Place of Origin:
China
Samples:
$1731654.0/piece | Min. order : 1 piece
Shipping:
Support Sea freight
Payments:
L/C,D/A,D/P,T/T,Western Union,MoneyGram,OA
Lead Time:
1-1(pieces):120(days),2-10(pieces):85(days),11-50(pieces):66(days),>50(pieces):To be negotiated(days)
model number:
HY-2504
brand name:
HYRT
design customization

    oops...!

    no product data.

    Go to homepage
    Required Products
    Total price discount:
    Flow range
    20-2500L
    working temperature
    4°C-40°C
    scale range
    0.4%-4%
    package size
    52X14X17
    OEM
    Accepted
    Diameter
    3/4
    Function
    Automatic Intelligent Liquid Doser Pump For Poultry Water System
    package
    colour carton
    Color
    Olive Green
    Working pressure
    0.2-8bar
    Product name
    Proportional Fertilizer pump
    material
    Reinforced nylon
    place of origin
    shandong
    type
    Other Watering & Irrigation

    Precise Reliable Compact Durable 

    Ensure consistent nutrient delivery and healthier flock growth with an automatic irrigation doser that precisely injects Fertilizer into poultry water lines, cutting labor and chemical waste. Built from reinforced nylon in an olive-green compact 3/4" diameter housing, its proportional dosing (0.2–2% scale) and 20–2500 L flow range handle varied flock sizes under 0.2–8 bar pressure and 4–40°C operation for reliable, long-lasting performance. Packed in eco-friendly color cartons (52×14×17 cm) and backed by pre-production samples, final inspections, OEM support and flexible shipping/payment options, it arrives ready to install for worry‑free dosing and maintenance.

    1620183233g0e
    1620183233oxz

    Automatic Poultry Irrigation Doser

    The HY-2504 Automatic Irrigation Doser Pump is a proportional Fertilizer injector built from reinforced nylon with a 3/4" connection, olive-green housing, and an adjustable dosing mechanism covering low-to-high concentration ranges while handling flows from 20–2500 L and pressures of 0.2–8 bar. It provides automatic, water-flow-synchronized Fertilizer dosing for poultry systems to ensure accurate nutrient delivery, reduce manual labor and chemical waste, and promote uniform flock hydration and growth. Compact, easy to install into standard irrigation lines, the intelligent pump operates reliably at 4–40°C, accepts OEM packaging, and is produced under strict pre-production sampling and final inspection quality controls.

    Automatic Poultry Fertilizer Doser 

    The HYRT HY-2504 proportional irrigation doser is an automatic, reinforced-nylon pump in olive green designed for poultry water systems, providing precise Fertilizer dosing with a scale range of 0.2–2% and flow coverage from 20–2500 L at 0.2–8 bar. Its compact 3/4" design works between 4°C and 40°C, accepts OEM customization, and is packaged in sturdy, eco-friendly cartons for safe delivery. Manufactured in Shandong with pre-production samples and final inspections, this intelligent liquid doser ensures reliable metering for drip, sprinkler, and fertilizer systems.


    ◎ product nicety 1 

    ◎ product nicety 2

    ◎ product nicety 3

    16201832330io
    1620183233rje

    Precise Automatic Poultry Nutrition

    Born from practical farm engineering and brand expertise, the Automatic Irrigation Doser Pump delivers precise 0.4–4% Fertilizer dosing for poultry drinking systems to promote uniform nutrient delivery and healthier flocks. Its robust, corrosion-resistant construction, adjustable flow controls, and programmable timing ensure reliable, low-maintenance operation with minimal chemical waste. Features and advantages include high dosing accuracy, compatibility with various liquid Fertilizer types and standard water lines, energy-efficient performance, easy installation, and intuitive controls that boost farm productivity and reduce labor.

    Material introduction

    The Automatic Irrigation Doser Pump features a reinforced nylon construction that provides a lightweight yet sturdy housing ideal for poultry water systems. Its olive-green reinforced nylon body and chemically resistant internal components are selected to withstand exposure to Fertilizer solutions while operating reliably across the 4°C–40°C temperature range and 0.2–8 bar working pressure. These material choices deliver long-term durability, consistent proportional dosing, and low maintenance for demanding irrigation and fertilization applications.


    ◎ Reinforced nylon housing 

    ◎ Chemical‑resistant construction

    ◎ Precision sealed assembly

    1620183233lpr

    FAQ

    1
    What does "0.4–4% dosing" mean and how do I calculate the amount of chemical to inject?
    0.4–4% is the adjustable injection ratio: the chemical flow divided by the main water flow, expressed as a percentage. Formula: Dose % = (injected chemical flow ÷ main water flow) × 100. Example: if your water flow is 100 L/min and you want 1% solution, you must inject 1 L/min of concentrate (100 × 0.01 = 1). Use the pump’s calibration chart or measure injected volume over time to set the correct stroke/setting.
    2
    How should I install and set up the doser pump in a poultry house?
    Mount the pump close to the chemical tank and near the water main or header to minimize suction length. Fit a suction hose with a foot/strainer valve to the chemical drum, and an injection point into the main water line after a shutoff and upstream of distribution lines. Always install a non-return/check valve and backflow prevention device to protect the water supply, and a filter on the water line to prevent solids reaching the nozzles. Prime the pump following the manual, power it, and verify output by measuring injected volume for a set time to confirm dosing percent.
    3
    What kinds of fluids can I use with this pump, and what should I avoid?
    Suitable fluids typically include water‑soluble fertilizers, most water‑based disinfectants, medications/supplements formulated for water administration, and other low‑viscosity, non‑abrasive solutions. Avoid thick suspensions, slurries, undissolved powders, corrosive strong acids or bases unless the pump materials are specified compatible, and flammable liquids. Always consult the chemical manufacturer and the pump’s materials‑compatibility chart before use.
    4
    How do I safely dose medications or disinfectants for poultry drinking water?
    Work with your veterinarian for correct drug and withdrawal guidance. Calculate the dose based on flock water consumption and the pump’s ratio. Flush lines before and after medicating to prevent residue/overdosing. Use backflow prevention to protect potable supplies. Ensure even distribution by checking flow and pressure to nipple/drinker lines, and monitor birds closely during and after treatment for adverse reactions.
    5
    What routine maintenance and troubleshooting steps should I follow?
    Maintenance: flush the system with clean water after each chemical use, inspect and replace suction tubing, diaphragms, valves, and seals per the manual (typical intervals depend on usage), and keep filters clean. Troubleshooting: if no injection—check suction line for air leaks, clogged strainer, closed valves, or an empty chemical tank; if low output—check worn diaphragm/valves or incorrect stroke setting; if pulsation—install a pulsation dampener or check suction stability; if leaking—replace seals and tighten fittings. Always depressurize before servicing.
    6
    In what application scenarios does this doser work best, and what are best practices?
    Best uses: fertigation for small/medium irrigation systems, greenhouse and crop applications needing accurate low-percentage fertilization, and poultry house applications such as dosing vitamins, medications, or sanitizers into drinking water and biosecurity flushing. Best practices: always use filtration and backflow prevention, calibrate the pump after installation and after any setting change, follow safety and PPE recommendations when handling chemicals, and tailor dosing schedules to flock or crop needs while monitoring response and water consumption.
    Contact Us
    Let' s Discuss Your Needs
    Our water-saving experts will provide you with full assistance from quotation to delivery.
    Write to Us
    18606348185@lwhyrt. com
    Support Center 24/7
    0086-18606348185
    Our Location
    No. 2, Wuhua Street, Fengcheng Industrial Park, Laiwu District, Jinan City, jinan, Shandong, China
    no data
    Related Products
    no data
    Shandong HYRT Water-saving Irrigation Co., Ltd.
    One-stop professional irrigation system manufacturer
    Customer service
    detect