Feature Highlights
Clean shutdowns and more efficient restarts
Dripping after pump shutdown is more than wasted water—it can create low-point ponding and leave irrigation zones drained before the next cycle. The HYRT anti-drip valve uses line pressure to operate automatically. It opens when pressure reaches the selected opening point and closes as pressure falls to the shut-off point, reducing continued drainage after the system stops. Three pressure ranges are available: opening at 0.6, 1.0 or 1.5 bar and closing at 0.3, 0.7 or 1.0 bar. This allows contractors and growers to match the valve to different system conditions. Connection options include 16/20, 1/2 inch and 3/4 inch, while the detachable construction supports routine cleaning. It is a practical control component for orchards, greenhouses, vegetable production and landscape irrigation.
Operating Principle: The valve opens at the specified opening pressure and closes as pressure falls to the shut-off point, reducing drainage after irrigation stops.
Core Advantages
Application Fields
The anti-drip valve is designed for orchards, greenhouses, vegetable farms and landscape systems that need to reduce shutdown drainage, control low-point dripping and maintain irrigation zones between cycles.
In zones with elevation changes, automatic shut-off reduces continued dripping from low-position emitters and helps avoid overly wet root areas.
Reduced post-shutdown dripping helps protect paths, benches and the working environment while supporting precise irrigation control.
Low-, medium- or high-pressure models can be selected to match system conditions and reduce unnecessary drainage between irrigation cycles.
Multiple connection sizes support lateral and end-line control while reducing concentrated drainage on slopes or low-lying areas.
Customized Services And Technical Support
Different irrigation networks require different opening and closing pressures. Shandong HYRT Water-Saving Irrigation Co., Ltd. supports pressure-range selection, connection matching and system configuration.
Installation and Maintenance Guide
● Selection: Confirm normal operating pressure and residual pressure after shutdown. Choose the low-, medium- or high-pressure model and the required connection size.
● Installation: Flush the pipeline before installation and follow the flow direction marked on the valve body. Secure both ends and install the valve where post-shutdown drainage must be controlled.
● Commissioning: Increase pressure slowly and confirm that water passes once the opening pressure is reached. After shutdown, check that flow stops around the specified closing pressure.
● Maintenance: Inspect filtration regularly. If operation becomes irregular, open the valve cover, remove debris, reassemble and repeat the pressure-rise and pressure-drop test.